Related Experiment Video
Updated: Jul 5, 2025

Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
Value and Variability of Pulse Shape Indicator for Estimating Mean Arterial Pressure in the Radial and Femoral
Mathieu Jozwiak1,2, Sandrine Millasseau3, Jean-Louis Teboul4
1Service de Médecine Intensive Réanimation CHU de Nice Nice France.
Background:
The form factor (FF) is a pulse shape indicator that corresponds to the fraction of pulse pressure added to diastolic blood pressure to estimate the time-averaged mean arterial pressure (MAP). Our invasive study assessed the FF value and variability at the radial and femoral artery levels and evaluated the recommended fixed FF value of 0.33.
Methods And Results:
Hemodynamically stable patients were prospectively included in 2 intensive care units. FF was documented at baseline and during dynamic maneuvers. A total of 632 patients (64±16 years of age, 66% men, MAP=81±14 mm Hg) were included. Among them, 355 (56%) had a radial catheter and 277 (44%) had a femoral catheter. The FF was 0.34±0.06. In multiple linear regression, FF was influenced by biological sex (P<0.0001) and heart rate (P=0.04) but not by height, weight, or catheter location. The radial FF was 0.35±0.06, whereas the femoral FF was 0.34±0.05 (P=0.08). Both radial and femoral FF were higher in women than in men (P<0.05). When using the 0.33 FF value to estimate MAP, the error was -0.4±4.0 mm Hg and -0.1±2.9 mm Hg at the radial and femoral level, respectively, and the MAP estimate still demonstrated high accuracy and good precision even after changes in norepinephrine dose, increase in positive end-expiratory pressure level, fluid administration, or prone positioning (n=218).
Conclusions:
Despite higher FF in women and despite interindividual variability in FF, using a fixed FF value of 0.33 yielded accurate and precise estimations of MAP. This finding has potential implications for blood pressure monitoring devices and the study of pulse wave amplification.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse Assessment Sites
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Special considerations while measuring pulse

