Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
Published on: July 26, 2024
Review of Gas-Chromatographic Measurement Methodologies for Atmospheric Halogenated Greenhouse Gases
Noh Soo Han1, Jeong Sik Lim1,2
1Greenhouse Gas Metrology Team of Advanced Instrumentation Institute, Korea Research Institute of Standards and Science (KRISS), Daejeon, Republic of Korea.
Abstract:
Gas chromatography (GC) is crucial for measuring atmospheric halogenated greenhouse gases (hGHGs), usually coupled with electron capture detector (ECD, with higher sensitivity) or mass spectrometry (MS, with higher selectivity). This review compares GC-ECD and GC-MS for analyzing atmospheric hGHGs in terms of analytical methodology, performance, and instrumentation. For hGHGs such as SF6, chlorofluorocarbons, and N2O, ECD can be employed in the single column, forecut-backflush (FCBF), and preconcentration methods. The order of appearance of SF6 and N2O is an important consideration for selecting the separation column to avoid chromatographic interference from the long-tailed N2O and O2 on SF6. Single column and FCBF GC-ECD methods suffer from nonlinear responsivity, but the preconcentration method can compensate for nonlinearity. The last method also offers a low drift, which eliminates the need for multipoint calibration and enables perfect linearity at atmospheric SF6 levels. GC-MS demonstrates strong separability and identification capabilities, and over 60 hGHGs can be qualitatively analyzed by leveraging the separation power of MS and established MS databases. However, GC-MS requires a preconcentrator operating at -165 °C utilizing specialized adsorbents. Two notable preconcentrator-GC-MS systems, Medusa-GC-MS and detachable trap preconcentrator (DTP) GC-MS, differ in trap design, temperature scheme, and separation column type. Medusa-GC-MS employs a three-phased temperature operation before MS. DTP-GC-MS separates the preconcentration cycle into highly and less volatile compounds, using a different temperature scheme from that of Medusa-GC-MS. The preconcentrator-GC-MS system is widely employed for measuring perfluorocarbons, hydrofluorocarbons, and other hGHGs. This method necessitates multiple adsorption traps to discriminate the most abundant air components.
More Related Videos
11:50Measurement of Greenhouse Gas Flux from Agricultural Soils Using Static Chambers
Published on: August 3, 2014
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...