Related Experiment Video
Updated: Jul 28, 2026

Extraction of Organochlorine Pesticides from Plastic Pellets and Plastic Type Analysis
Published on: July 1, 2017
Development of novel methods based on GC-HRMS and LC-HRMS for the determination of non-phthalate plasticizers in soil
Raquel Capilla-Flores1, Gonzalo Egea-Castro1, Rosalía López-Ruíz1
1Research Group "Analytical Chemistry of Contaminants", Department of Chemistry and Physics, Research Centre for Mediterranean Intensive Agrosystems and Agri-Food Biotechnology (CIAIMBITAL), University of Almeria, Agrifood Campus of International Excellence, ceiA3, E-04120 Almeria, Spain.
Abstract:
Non-phthalate plasticizers (NPPs) are a suitable alternative to phthalates, which are harmful compounds for human, animal health, and the environment. In this study, 28 commercial non-phthalate plasticizers (NPPs) from different families, including adipates, citrates, phosphates, sebacates, trimellitates, benzoates and cyclohexanoates, were determined. Two novel methods for determining these alternative compounds in soil were developed using gas chromatography coupled to high-resolution mass spectrometry (GC-HRMS-Q-Orbitrap) and liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS-Q-Orbitrap). Solid-liquid extraction (SLE) with ethyl acetate or acetonitrile, along with water as extraction solvents, were employed. In most cases, the GC method exhibited recoveries ranging from 84.9 % to 110.8 % at 20, 40 and 200 μg/kg, while the LC method achieved recoveries between 73.1 % and 115.4 % at 10, 20, 40 and 200 μg/kg. Most of the relative standard deviation (RSD) values were below 20 % for both methods. The validated methods were then applied to analyse soil samples collected from four different areas in Almeria. The results indicated that the compounds detected most frequently at high concentrations were 1-hydroxycyclohexyl phenyl ketone (HCPK) using GC, in the range 29.1-67.4 μg/kg and 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB) using LC, in the range 39.9-51.5 μg/kg. Additionally, suspect and unknown analysis were carried out, and other plasticizers as phthalates, were also detected, in addition to other substances present in the analysed samples. All the soils exhibited the presence of a few plasticizers, either phthalic and/or non-phthalic.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Bioplastics