Towards Zero Phrenic Nerve Injury in Reoperative Pediatric Cardiac Surgery: The Value of Intraoperative Phrenic Nerve
Sameh M Said1,2, Ali H Mashadi3, Mahmoud I Salem4
1Division of Pediatric and Adult Congenital Cardiac Surgery, Maria Fareri Children's Hospital, Westchester Medical Center, Valhalla, NY 10595, USA.
Background:
Phrenic nerve injury is a devastating complication that results in significant morbidity and mortality. We developed a novel technique to localize the phrenic nerve and evaluate its success.
Methods:
Two groups of children underwent repeat sternotomy for a variety of indications. Group I (69 patients, nerve stimulator) and Group II (78 patients, no nerve stimulator).
Results:
There was no significant difference in the mean age and weight between the two groups: (6.4 ± 6.5 years vs. 5.6 ± 6.4 years; p = 0.65) and (25.2 ± 24.1 vs. 22.6 ± 22.1; p = 0.69), respectively. The two groups were comparable in the following procedures: pulmonary conduit replacement, bidirectional cavopulmonary anastomosis, aortic arch repair, and Fontan, while Group I had more pulmonary arterial branch reconstruction (p = 0.009) and Group II had more heart transplant patients (p = 0.001). There was no phrenic nerve injury in Group I, while there were 13 patients who suffered phrenic nerve injury in Group II (p < 0.001). No early mortality in Group I, while five patients died prior to discharge in Group II. Eleven patients underwent diaphragm plication in Group II (p = 0.001). The mean number of hours on the ventilator was significantly higher in Group II (137.3 ± 324.9) compared to Group I (17 ± 66.9), p < 0.001. Group II had a significantly longer length of ICU and hospital stays compared to Group I (p = 0.007 and p = 0.006 respectively).
Conclusion: