Related Experiment Video
Updated: Jul 5, 2025

Multiple Intravenous Bolus Dosing and Invasive Hemodynamic Assessment in a Hypoxia-Induced Mouse Pulmonary Artery Hypertension Model
Published on: November 11, 2022
Evaluation of common clinical and hemodynamic parameters to pulmonary capillary wedge pressures in patients
Kyle M Hocking1,2, Jessica Huston3, Jeffery Schmeckpeper4
1Department of Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.
Introduction:
A cornerstone of heart failure assessment is the right heart catheterization and the pulmonary capillary wedge pressure measurement it can provide. Clinical and hemodynamic parameters such as weight and jugular venous distention are less invasive measures often used to diagnose, manage, and treat these patients. To date, there is little data looking at the association of these key parameters to measured pulmonary capillary wedge pressure (PCWP). This is a large, retrospective, secondary analysis of a right heart catheterization database comparing clinical and hemodynamic parameters against measured PCWP in heart failure patients.
Methods:
A total of 538 subjects were included in this secondary analysis. Spearman's Rho analysis of each clinical and hemodynamic variable was used to compare their association to the documented PCWP. Variables analyzed included weight, body mass index (BMI), jugular venous distention (JVD), creatinine, edema grade, right atrial pressure (RAP), pulmonary artery systolic pressure (PASP), systemic vascular resistance, pulmonary vascular resistance, cardiac output (thermal and Fick), systolic blood pressure, diastolic blood pressure, heart rate, respiratory rate, oxygen saturation (SpO2), and pulmonary artery diastolic pressure (PADP).
Results:
Ten out of 17 selected parameters had a statistically significant association with measured PCWP values. PADP had the strongest association (0.73, p<0.0001), followed by RAP and PASP (0.69, p<0.0001 and 0.67, p<0.0001, respectively). Other significant parameters included weight (0.2, p<0.001), BMI (0.2, p<0.001), SpO2 (-0.17, p<0.0091), JVD (0.24, p<0.005) and edema grade (0.2, p<0.0001).
Conclusion:
This retrospective analysis clarifies the associations of commonly used clinical and hemodynamic parameters to the clinically used gold standard for volume assessment in heart failure patients, PCWP.