Predicting Egg Storage Time with a Portable Near-Infrared Instrument: Effects of Temperature and Production System
Daniel Cozzolino1, Pooja Sanal2, Jana Schreuder3
1Centre for Nutrition and Food Sciences, Queensland Alliance for Agriculture and Food Innovation (QAAFI), The University of Queensland, St. Lucia, Brisbane, QLD 4072, Australia.
Abstract:
Determining egg freshness is critical for ensuring food safety and security and as such, different methods have been evaluated and implemented to accurately measure and predict it. In this study, a portable near-infrared (NIR) instrument combined with chemometrics was used to monitor and predict the storage time of eggs under two storage conditions-room temperature (RT) and cold (CT) storage-from two production systems: cage and free-range. A total of 700 egg samples were analyzed, using principal component analysis (PCA) and partial least squares (PLS) regression to analyze the NIR spectra. The PCA score plot did not show any clear separation between egg samples from the two production systems; however, some egg samples were grouped according to storage conditions. The cross-validation statistics for predicting storage time were as follows: for cage and RT eggs, the coefficient of determination in cross validation (R2CV) was 0.67, with a standard error in cross-validation (SECV) of 7.64 days and residual predictive deviation (RPD) of 1.8; for CT cage eggs, R2CV of 0.84, SECV of 5.38 days and RPD of 3.2; for CT free-range eggs, R2CV of 0.83, SECV of 5.52 days and RPD of 3.2; and for RT free-range eggs, R2CV of 0.82, SECV of 5.61 days, and RPD of 3.0. This study demonstrated that NIR spectroscopy can predict storage time non-destructively in intact egg samples. Even though the results of the present study are promising, further research is still needed to further extend these results to other production systems, as well as to explore the potential of this technique to predict other egg quality parameters associated with freshness.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Physical Methods for Controlling Microbial Growth: Temperature
Pasteurization and Food Preservation
Methods of Controlling Food Spoilage