Related Experiment Video
Updated: Aug 15, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Continuous measurement of oxygen uptake. Evaluation of the Engström metabolic computer and clinical experiences
Abstract:
A new system for continuous measurement of oxygen uptake was tested. The tidal volumes delivered by the system, the accuracy of the oxygen sensor cell, measurement of the oxygen uptake at different inspired oxygen concentrations, and comparative tests of oxygen uptake using the Fick principle were studied. Judging from our results, even thorough maintenance could not entirely prevent leakages. Due to a construction error, there was a large increase in measured oxygen uptake if inspired oxygen concentration was increased. While carbon-dioxide output was constant, this led to respiratory quotients of less than 0.5. By modifying the system with a mixing chamber for the inspiratory gas, new tubing to the oxygen sensor cell and changes in the computer software, these errors have been corrected in the meantime. In comparative tests of oxygen uptake using the Fick principle (cardiac output and arteriovenous oxygen content difference), we found a mean difference between EMC and the Fick principle of about 6.6% (P less than or equal to 0.001, r = 0.91) with nearly identical standard deviations for both values. Our experience indicates that the EMC is suitable for continuous measurements of oxygen uptake. Additional technical improvements seem to be possible.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...