Effect of Respiratory Failure on Peripheral and Organ Perfusion Markers in Severe COVID-19: A Prospective Cohort
Mateusz Gutowski1, Jakub Klimkiewicz1, Bartosz Rustecki1
1Department of Anesthesiology and Intensive Care, Military Institute of Medicine-National Research Institute, 04-141 Warsaw, Poland.
Abstract:
Microvascular dysfunction and inflammation caused by COVID-19 disrupt organ function. The study aimed to investigate the association between the severity of SARS-CoV-2 pneumonia and peripheral and organ perfusion as a consequence of altered microcirculation. A total of 116 patients hospitalized due to severe COVID-19 were enrolled in the study. On admission, the patients underwent a Capillary Refill Time (CRT) examination, finger oxygen saturation measurement, thermal imaging of the hand (FIT), and a kidney Doppler ultrasound. Medical data were collected from the medical history. From the evaluated perfusion parameters, only renal cortex perfusion (RCP) was substantially correlated with the CT score (p < 0.010). The peripheral perfusion parameters of Sat., FIT, CRT, and RCP correlated with the ARDS stages (p = 0.0021; p = 0.038; p < 0.0006; p < 0.0002, respectively). The Oxygenation Ratio value (p < 0.001) was significantly associated with all the perfusion parameters (saturation, CRT, FIT, and RCP) in the multivariable regression analysis model. According to the stepwise retrograde regression analysis, RCP was an independent parameter linked with the Oxygenation Ratio (p < 0.001). Severe COVID-19 can result in microvascular dysfunction influencing peripheral and organ perfusion, which can be measured with various methods. The staging of COVID-19 assessed by CT and the Oxygenation Ratio correlates with RCP, CRT, FIT, and oxygen saturation.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
09:47Author Spotlight: Utilizing Next-Generation Polymerized Human Hemoglobin for Improved Donor Lung Evaluation and Preservation in Rats
Published on: June 14, 2024
Related Concept Videos
Acute Respiratory Failure-IV
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-III
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
