Karl Henrik May1,2, Shiva Mohammadzadeh1, Andreas Keil1,3
1Fraunhofer Insititute for Industrial Mathematics ITWM, 67663 Kaiserslautern, Germany.
Multi-channel terahertz tomography systems accelerate defect detection in dielectric materials. An eight-channel frequency-modulated continuous wave (FMCW) setup with an f-θ lens significantly boosts acquisition speed for industrial applications.
Area of Science:
- Non-destructive testing
- Terahertz imaging
- Dielectric material analysis
Background:
- Terahertz tomography enhances non-destructive inspection of dielectric samples.
- Recent advancements improved image quality using prior information and off-axis data.
- Increased measurement time limits industrial applicability.
Purpose of the Study:
- To develop and evaluate multi-channel terahertz tomography systems for faster data acquisition.
- To compare imaging performance against single-pixel setups.
- To enable industrial applications of terahertz tomography.
Main Methods:
- Development of two tomographic frequency-modulated continuous wave (FMCW) systems (230-320 GHz) with eight-channel detector arrays.
- Comparison of a system using channels for refracted radiation with one employing an f-θ lens for direct array utilization.
- Evaluation against a single-pixel setup.
Main Results:
- Both multi-channel systems were compared to a single-pixel setup.
- The system with an f-θ lens and scanning mirror achieved a four to five-fold increase in acquisition speed.
- This configuration eliminates the need for slow transmitter translation.
Conclusions:
- Multi-channel detector arrays significantly accelerate terahertz tomography.
- The f-θ lens integrated system offers a substantial speed increase for industrial inspection.
- Optimized FMCW systems pave the way for efficient, high-speed non-destructive testing.
More Related Videos
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Related Concept Videos
Total Internal Reflection Fluorescence Microscopy
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...