Towards Precision Medicine in Clinical Practice: Alinity C vs. UHPLC-MS/MS in Plasma Aripiprazole Determination
Francisco José Toja-Camba1,2,3, Enrique Bandín-Vilar1,2,3, Gonzalo Hermelo-Vidal2
1Pharmacy Department, University Clinical Hospital of Santiago de Compostela (SERGAS), 15706 Santiago de Compostela, Spain.
Abstract:
Therapeutic drug monitoring improves the benefit-risk balance of antipsychotic therapy. Ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) is considered the gold-standard method for measuring plasma drug concentrations; however, the Alinity C system has emerged as a promising alternative. This is the first study aimed at comparing UHPLC-MS/MS versus Alinity C in measuring plasma concentrations of aripiprazole and dehydroaripiprazole. A total of 86 plasma samples were analyzed. The active moiety of aripiprazole was measured in 60 samples using both systems and 26 samples were analyzed twice using Alinity C with an intermediate period of 6 months to assess its reproducibility. Spearman's correlation revealed a good association between the two assays (rs = 0.96) and no significance differences were found by McNemar's test when classifying samples between infra-, supra- and therapeutic ranges. Passing-Bablock regression showed a good correlation among methods (rs = 0.93) and a slope of 1.12 indicating a slight tendency of Alinity C to measure higher values than UHPLC-MS/MS. In addition, a good intra-method correlation across the two sequential analyses with Alinity C was obtained (rs = 0.99). Nonetheless, clinical decisions could be different in 15% of the cases depending on the chosen method. No differences were found in active moiety determination by Alinity C depending on the concentration of aripiprazole and dehydroaripiprazole of the samples.
More Related Videos
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences