A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Clinical value of 18F-PSMA-1007 PET/MRI in primary staging of patients with intermediate- to high-risk prostate
Ismail Ali1, Mahmoud Rezk2, Dalia Hamouda3
1Radiology Department, Faculty of Human Medicine, Zagazig University, Zagazig, Faculty of medicine street, Zagazig, Sharkia, 44519, Egypt.
Objective:
To assess the utility of 18F-PSMA-1007 PET/MRI in initial staging of intermediate- to high-risk prostate cancer (HRPCa).
Methods:
A total of 46 patients with pathologically verified intermediate and/or HRPCa who underwent 18F-PSMA-1007 PET/MRI with dedicated pelvic high-resolution multiparametric MRI (mpMRI) were included.
Results:
PET/MRI showed 100% sensitivity (SN), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), and accuracy in detecting seminal vesicle (SV) and rectal invasion, versus 87.5%, 100%, 100% 93.8%, 95.7% and 50%, 100%,100%, 95.5%, and 95.7% for mpMRI respectively. However, PET/MRI had poor SN (40% and 0%) but high SP (94.4% and 100%) in detection of UB and neurovascular bundle (NV) invasion compared to 100% SN and SP for mpMRI. PET/MRI demonstrated stronger TNM staging agreement with the gold standard than mpMRI-WBMRI. It demonstrated concordance with T, N, and M stages in 40, 41, and 36 patients (k 0.84, 0.60, and 0.68, respectively) versus 29, 33, and 31 patients (k 0.54, 0.22, and 0.50) with accurate over all staging of 38/46 patients versus 30/46 patients (K 0.52 versus 0.22).
Conclusion:
18F-PSMA-1007 PET/MRI is a promising imaging modality with high diagnostic accuracy in staging intermediate- and HRPCa; it improves local tumour evaluation and provides precise TNM staging.
Advances In Knowledge:
18F-PSMA-1007 PET/MRI could have high diagnostic accuracy as shown in the current study for staging HRPCa patients that is crucial for treatment selection. We think that our study will contribute to the body of knowledge and improve the literature surrounding the clinical uses of integrated 18F-PSMA-1007 PET/MRI.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:54MR Molecular Imaging of Prostate Cancer with a Small Molecular CLT1 Peptide Targeted Contrast Agent
Published on: September 3, 2013
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET