Related Experiment Video
Updated: Jul 5, 2025

A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
Duplicate measures of hemoglobin mass within an hour: feasibility, reliability, and comparison of three devices in
Andreas Breenfeldt Andersen1, Thomas Christian Bonne2, Nikolai Baastrup Nordsborg2
1Department of Public Health, Research Unit for Exercise Biology, Aarhus University, Aarhus, Denmark.
Abstract:
Duplicate measure of hemoglobin mass by carbon monoxide (CO)-rebreathing is a logistical challenge as recommendations prompt several hours between measures to minimize CO-accumulation. This study investigated the feasibility and reliability of performing duplicate CO-rebreathing procedures immediately following one another. Additionally, it was evaluated whether the obtained hemoglobin mass from three different CO-rebreathing devices is comparable. Fifty-five healthy participants (22 males, 23 females) performed 222 duplicate CO-rebreathing procedures in total. Additionally, in a randomized cross-over design 10 participants completed three experimental trials, each including three CO-rebreathing procedures, with the first and second separated by 24 h and the second and third separated by 5-10 min. Each trial was separated by >48 h and conducted using either a glass-spirometer, a semi-automated electromechanical device, or a standard three-way plastic valve designed for pulmonary measurements. Hemoglobin mass was 3 ± 22 g lower (p < 0.05) at the second measure when performed immediately after the first with a typical error of 1.1%. Carboxyhemoglobin levels reached 10.9 ± 1.3%. In the randomized trial, hemoglobin mass was similar between the glass-spirometer and three-way valve, but ∼6% (∼50 g) higher for the semi-automated device. Notably, differences in hemoglobin mass were up to ∼13% (∼100 g) when device-specific recommendations for correction of CO loss to myoglobin and exhalation was followed. In conclusion, it is feasible and reliable to perform two immediate CO-rebreathing procedures. Hemoglobin mass is comparable between the glass-spirometer and the three-way plastic valve, but higher for the semi-automated device. The differences are amplified if the device-specific recommendations of CO-loss corrections are followed.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

