Related Experiment Video
Updated: Jul 5, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Real-world glycaemic outcomes in patients with type 1 diabetes using glucose sensors-Experience from a single centre
Robert E Lyons1, Roshaida Abdul Wahab2, Sue Yee Goh3
1Endocrinology and Diabetes Unit, St. Columcille's Hospital, Dublin, Ireland.
Aims:
To evaluate changes in glycated haemoglobin (HbA1 c) and sensor-based glycaemic metrics after glucose sensor commencement in adults with T1D.
Methods:
We performed a retrospective observational single-centre study on HbA1 c, and sensor-based glycaemic data following the initiation of continuous glucose monitoring (CGM) in adults with T1D (n = 209).
Results:
We observed an overall improvement in HbA1 c from 66 (59-78) mmol/mol [8.2 (7.5-9.3)%] pre-sensor to 60 (53-71) mmol/mol [7.6 (7.0-8.6)%] on-sensor (p < .001). The pre-sensor HbA1 c improved from 66 (57-74) mmol/mol [8.2 (7.4-8.9)%] to 62 (54-71) mmol/mol [7.8 (7.1-8.7)%] within the first year of usage to 60 (53-69) mmol/mol [7.6 (7.0-8.4)%] in the following year (n = 121, p < .001). RT-CGM-user had a significant improvement in HbA1 c (Dexcom G6; p < .001, r = 0.33 and Guardian 3; p < .001, r = 0.59) while a non-significant reduction was seen in FGM-user (Libre 1; p = .279). Both MDI (p < .001, r = 0.33) and CSII group (p < .001, r = 0.41) also demonstrated significant HbA1 c improvement. Patients with pre-sensor HbA1 c of ≥64 mmol/mol [8.0%] (n = 125), had attenuation of pre-sensor HbA1 c from 75 (68-83) mmol/mol [9.0 (8.4-9.7)%] to 67 (59-75) mmol/mol [8.2 (7.6-9.0)%] (p < .001, r = 0.44). Altogether, 25.8% of patients achieved the recommended HbA1 c goal of ≤53 mmol/mol and 16.7% attained the recommended ≥70% time in range (3.9-10.0 mmol/L).
Conclusions:
Our study demonstrated that minimally invasive glucose sensor technology in adults with T1D is associated with improvement in glycaemic outcomes. However, despite significant improvements in HbA1 c, achieving the recommended goals for all glycaemic metrics remained challenging.
More Related Videos
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Symptoms, Diagnosis, and Complications
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Oral Hypoglycemic Agents: Glinides

