Related Experiment Video
Updated: Jul 5, 2025

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
[Safety of modified T-piece resuscitator versus nasal cannula oxygen in electronic bronchoscopy for infants: a
Jun-Jie Ning1, Zhi-Hui Zuo1, Zhi-Dong Yu1
1Pediatric Intensive Care Unit, West China Second University Hospital, Sichuan University, Chengdu 610041, China; National Health Commission Key Laboratory of Chronobiology (Sichuan University), Chengdu 610041, China; Key Laboratory of Birth Defects and Related Diseases of Women and Children, Chengdu 610041, China (Qiao L-N, Email: qiaolina@scu.edu. cn).
Objectives:
To optimize the oxygen therapy regimens for infants with pulmonary diseases during bronchoscopy.
Methods:
A prospective randomized, controlled, and single-center clinical trial was conducted on 42 infants who underwent electronic bronchoscopy from July 2019 to July 2021. These infants were divided into a nasal cannula (NC) group and a modified T-piece resuscitator (TPR) group using a random number table. The lowest intraoperative blood oxygen saturation was recorded as the primary outcome, and intraoperative heart rate and respiratory results were recorded as the secondary outcomes.
Results:
Compared with the NC group, the modified TPR group had a significantly higher level of minimum oxygen saturation during surgery and a significantly lower incidence rate of hypoxemia (P<0.05). In the modified TPR group, there were 6 infants with mild hypoxemia, 2 with moderate hypoxemia, and 1 with severe hypoxemia, while in the NC group, there were 3 infants with mild hypoxemia, 5 with moderate hypoxemia, and 9 with severe hypoxemia (P<0.05). The modified TPR group had a significantly lower incidence rate of intraoperative respiratory rhythm abnormalities than the NC group (P<0.05), but there was no significant difference in the incidence rate of arrhythmias between the two groups (P>0.05).
Conclusions:
Modified TPR can significantly reduce the risk of hypoxemia in infants with pulmonary diseases during electronic bronchoscopy, and TPR significantly decreases the severity of hypoxemia and the incidence of respiratory rhythm abnormalities compared with traditional NC.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...