Related Experiment Video
Updated: Jul 4, 2025

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Echocardiographic characteristics in neonates with septic shock
Kumari Gunjan1, Manoj Modi1, Anup Thakur1
1Department of Neonatology, Institute of Child Health, Sir Ganga Ram Hospital, New Delhi, India.
Abstract:
Clinical parameters used for hemodynamic assessment and titration of vasopressor therapy in neonates with septic shock have several limitations. Functional echocardiography is an emerging tool for bedside assessment of cardiac function and may be useful for diagnosis of shock and assessing the response to therapy. Data regarding echocardiographic parameters in neonates with shock is lacking. This prospective observational study was conducted in a Level III NICU with the primary objective of comparing echocardiographic characteristics of neonates with septic shock at diagnosis, following fluid boluses, and after maximum inotropic support [A1]. Additionally, we compared these characteristics with those of healthy stable neonates who were gestation and postnatal age-matched. A total of 36 neonates with septic shock and 30 gestation and postnatal age-matched controls were enrolled. The mean (SD) gestation and birth weight of neonates with septic shock were 30.6 (4.0) weeks and 1538 (728) g, respectively. Gram-negative bacilli constituted 78.9% of all isolates. At presentation, there was no significant difference between neonates with shock and controls in terms of ventricular outputs, shortening fraction, ratio of early to late diastolic trans-mitral flow velocity, and myocardial performance indices. The distensibility index of inferior vena cava was higher in neonates with shock compared to controls, (17% vs 10%, (p < 0.01)). Left ventricular output was 209 (92) and 227 (102) ml/kg/min (p = 0.53) and right ventricular output was 427 (203) and 459 (227) ml/kg/min, (p = 0.03), respectively, before and after inotropic therapy. Conclusion: Echocardiographic parameters may not differentiate neonates with septic shock from hemodynamically stable neonates. Neonates with shock associated with predominantly gram-negative sepsis are not able to augment cardiac functions, either at the onset or after administration of inotropes. Trial registration: (CTRI/2017/12/010766). What is known: • For neonates with shock, echocardiography is becoming increasingly popular as an objective method of evaluating hemodynamics. • In healthy preterm neonate, cardiac output has been known to increase in response to altered hemodynamics during states of increased oxygen demand. What is new: • In the setting of septic shock induced by gram-negative organisms, echocardiographic parameters are less likely to assist in the assessment of the response to vasoactive agents. Cytokines, induced by gram-negative organisms, may alter adrenoreceptors in myocardium and vasculature.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...