A rapid response time gas detector with embedded glass plates for digital radiography systems
1Institute of Nuclear and New Energy Technology, Tsinghua University, 100084, Beijing, China; Beijing Key Laboratory of Nuclear Detection Technology, 100084, Beijing, China.
Abstract:
The response time of a detector stands as a critical parameter in radiation imaging systems. However, the existing parallel plate ionization chamber detector manifests a noteworthy delay in response time, leading to the production of blurred radiation images. To enhance the image quality of radiation imaging systems, it becomes imperative to modify the electrode structure of the detector and consequently reduce the response time. We propose a gas ionization chamber detector incorporating a glass plate, resulting in a notably swift response time. The COMSOL software is employed to calculate the electric and weighting fields within the detector, while Garfield++ software is utilized to derive the output signal, including information on the response time. To validate the simulation data, an experimental ionization chamber underwent testing on a dedicated platform to acquire the output signal. The results revealed that the average electric field intensity in the induced region of the grid detector was increased by at least 10%. The detector response time was reduced to 50%-28% of that of the parallel plate detector. However, this improvement comes at the cost of a decrease in the detector's sensitivity. The incorporation of glass plates in a parallel plate detector offers a substantial improvement in the time response characteristics of a gas ionization chamber detector, thereby suggesting a valuable direction for future advancements in ionization chamber technology.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
10:16Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors