Optimal allocation of distributed energy storage systems to enhance voltage stability and minimize total cost
Ramy Mohamed Hany1, Tarek Mahmoud2, El Said Abd El Aziz Osman2
1Department of Electrical Power and Machines Engineering, The Higher Institute of Engineering, Elshorouk City, Egypt.
Abstract:
The enhancement of energy efficiency in a distribution network can be attained through the adding of energy storage systems (ESSs). The strategic placement and appropriate sizing of these systems have the potential to significantly enhance the overall performance of the network. An appropriately dimensioned and strategically located energy storage system has the potential to effectively address peak energy demand, optimize the addition of renewable and distributed energy sources, assist in managing the power quality and reduce the expenses associated with expanding distribution networks. This study proposes an efficient approach utilizing the Dandelion Optimizer (DO) to find the optimal placement and sizing of ESSs in a distribution network. The goal is to reduce the overall annual cost of the system, which includes expenses related to power losses, voltage deviation, and peak load damand. The methods outlined in this study is implemented on the IEEE 33 bus distribution system. The outcomes obtained from the proposed DO are contrasted with those of the original system so as to illustrate the impact of ESSs location on both the overall cost and voltage profile. Furthermore, a comparison is made between the outcomes of the Ant Lion Optimizer (ALO) and the intended Design of Experiment DO, revealing that the DO has obtained greater savings in comparison to the ALO. The recommended methodology's simplicity and efficacy in resolving the researched optimization issue make the acquired locations and sizes of ESSs favorable for implementation within the system.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
Related Concept Videos
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Distribution Reliability and Automation
Fast Decoupled and DC Powerflow
Primary Distribution
Energy Diagrams - II
The point in the energy diagram at which the system’s potential energy is the lowest is known as the local minima. The system tends to stay in this position indefinitely unless acted upon by a net force. The slope of the potential energy diagram at the local minima is zero, indicating that zero net force is acting on the system. The...