Assessing the Validity of Several Heart Rate Monitors in Wearable Technology While Mountain Biking
Bryson Carrier1, R W Salatto2, Dustin W Davis1
1University of Nevada, Las Vegas; Department of Kinesiology and Nutrition Sciences.
Purpose:
This study sought to assess the validity of several heart rate (HR) monitors in wearable technology during mountain biking (MTB), compared to the Polar H7® HR monitor, used as the criterion device.
Methods:
A total of 20 participants completed two MTB trials while wearing six HR monitors (5 test devices, 1 criterion). HR was recorded on a second-by-second basis for all devices analyzed. After data processing, validity measures were calculated, including 1. error analysis: mean absolute percentage errors (MAPE), mean absolute error (MAE), and mean error (ME), and 2. Correlation analysis: Lin's concordance correlation coefficient (CCC) and Pearson's correlation coefficient (r). Thresholds for validity were set at MAPE < 10% and CCC > 0.7.
Results:
The only device that was found to be valid during mountain biking was the Suunto Spartan Sport watch with accompanying HR monitor, with a MAPE of 0.66% and a CCC of 0.99 for the overall, combined data.
Conclusion:
If a person would like to track their HR during mountain biking, for pacing, training, or other reasons, the devices best able to produce valid results are chest-based, wireless electrocardiogram (ECG) monitors, secured by elastic straps to minimize the movement of the device, such as the Suunto chest-based HR monitor.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Errors occurring during blood pressure monitoring
Several factors...