Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Near-Infrared Off-Axis Cavity-Enhanced Optical Frequency Comb Spectroscopy for CO2/CO Dual-Gas Detection Assisted by
Gangyun Guan1, Anqi Liu1, Xuyang Wu1
1State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P.R. China.
Abstract:
Cavity-enhanced direct frequency comb spectroscopy (CE-DFCS) is widely used as a highly sensitive gas sensing technology in various gas detection fields. For the on-axis coupling incidence scheme, the detection accuracy and stability are seriously affected by the cavity-mode noise, and therefore, stable operation inevitably requires external electronic mode-locking and sweeping devices, substantially increasing system complexity. To address this issue, we propose off-axis cavity-enhanced optical frequency comb spectroscopy from both theoretical and experimental aspects, which is applied to the detection of single- and dual-gas of carbon monoxide (CO) and carbon dioxide (CO2) in the near-infrared. An erbium-doped fiber frequency comb with a repetition frequency of ∼41.709 MHz is coupled into a resonant cavity with a length of ∼360 mm in an off-axis manner, exciting numerous high-order modes to effectively suppress cavity-mode noise. The performance of multiple machine learning models is compared for the inversion of a single/dual gas concentration. A few absorbance spectra are collected to build a sample data set, which is then utilized for model training and learning. The results demonstrate that the Particle Swarm Optimization Support Vector Machine (PSO-SVM) model achieves the highest predictive accuracy for gas concentration and is ultimately applied to the detection system. Based on Allan deviation, the detection limit for CO in single-gas detection can reach 8.247 parts per million by volume (ppmv) by averaging 87 spectra. Meanwhile, for simultaneous CO2/CO measurement with highly overlapping absorbance spectra, the LoD can be reduced to 13.196 and 4.658 ppmv, respectively. The proposed optical gas sensing technique indicates the potential for the development of a field-deployable and intelligent sensor system capable of simultaneous detection of multiple gases.
Related Concept Videos
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Gas Chromatography: Types of Detectors-II
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
IR Absorption Frequency: Hybridization
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that...