Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

197
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
197
Aliasing01:18

Aliasing

136
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
136
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.4K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Diffusion models for medical image reconstruction.

BJR artificial intelligence·2026
Same author

AI for PET image reconstruction.

The British journal of radiology·2023
Same author

Deep Learning Signal Discrimination for Improved Sensitivity at High Specificity for CMOS Intraoperative Probes.

IEEE transactions on radiation and plasma medical sciences·2022
Same author

A Comparison of Cranial Cavity Extraction Tools for Non-contrast Enhanced CT Scans in Acute Stroke Patients.

Neuroinformatics·2021
Same author

Model-Based Deep Learning PET Image Reconstruction Using Forward-Backward Splitting Expectation-Maximization.

IEEE transactions on radiation and plasma medical sciences·2021
Same author

MR-guided motion-corrected PET image reconstruction for cardiac PET-MR.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2021
Same journal

Impact of DOI Capability on Detector Performance: A Comparative Study of DOI and Non-DOI Detectors for High-Resolution and Sensitivity Organ-Specific PET Inserts.

IEEE transactions on radiation and plasma medical sciences·2026
Same journal

Evaluation of a PET Insert for Trimodal Imaging: A Step Toward PET/MRI-Guided Focused Ultrasound.

IEEE transactions on radiation and plasma medical sciences·2026
Same journal

CHEMONO: a Cherenkov-Only Monolithic Detector for PGI in Proton Range Verification.

IEEE transactions on radiation and plasma medical sciences·2026
Same journal

A Virtual Clinical Trial to Detect Changes in Tumor Uptake with PET using Lesion Embedding.

IEEE transactions on radiation and plasma medical sciences·2026
Same journal

Quantitative evaluation of spatially-variant deformations recovered by deep learning on clinical-like breast lesions.

IEEE transactions on radiation and plasma medical sciences·2026
Same journal

Impact of detector parameters and image resolution modeling on dedicated brain PET imaging.

IEEE transactions on radiation and plasma medical sciences·2026
See all related articles

Related Experiment Video

Updated: Jul 4, 2025

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.5K

Synthesized Image Reconstruction for Post-Reconstruction Resolution Recovery.

Laurence Vass1, Andrew J Reader1

  • 1School of Biomedical Engineering and Imaging SciencesKing's College London WC2R 2LS London U.K.

IEEE Transactions on Radiation and Plasma Medical Sciences
|January 31, 2024
PubMed
Summary
This summary is machine-generated.

This study introduces a novel post-reconstruction method for positron emission tomography (PET) resolution recovery (RR). The technique enhances image quality by synthesizing data, improving accuracy in PET imaging.

Keywords:
Image reconstructionpositron emission tomography (PET)resolution recovery (RR)

More Related Videos

High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip
14:09

High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip

Published on: November 16, 2019

6.9K
Super-Resolution Imaging to Study Co-Localization of Proteins and Synaptic Markers in Primary Neurons
14:02

Super-Resolution Imaging to Study Co-Localization of Proteins and Synaptic Markers in Primary Neurons

Published on: October 31, 2020

5.8K

Related Experiment Videos

Last Updated: Jul 4, 2025

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.5K
High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip
14:09

High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip

Published on: November 16, 2019

6.9K
Super-Resolution Imaging to Study Co-Localization of Proteins and Synaptic Markers in Primary Neurons
14:02

Super-Resolution Imaging to Study Co-Localization of Proteins and Synaptic Markers in Primary Neurons

Published on: October 31, 2020

5.8K

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Image Reconstruction

Background:

  • Positron emission tomography (PET) imaging suffers from spatial resolution losses affecting quantification.
  • Current resolution recovery (RR) techniques often require complex integration of point spread function (PSF) modeling into 3-D reconstruction.
  • Existing post-reconstruction methods like Richardson-Lucy (RL) algorithm amplify noise early in iterations, leading to suboptimal image quality.

Purpose of the Study:

  • To develop a practical post-reconstruction RR method for PET imaging.
  • To improve image quality and quantification accuracy in PET scans.
  • To avoid the need for scanner-specific projectors and raw sinogram data.

Main Methods:

  • Proposed a novel post-reconstruction RR method.
  • Synthesized PET data via forward projection of an initial reconstruction.
  • Incorporated a modeled PSF into the system model during the reconstruction of synthetic data.

Main Results:

  • The proposed method demonstrated improved image quality compared to the Richardson-Lucy algorithm.
  • Achieved better image quality than standard RL iterations.
  • Successfully avoided the requirement for scanner-specific projectors and raw sinogram data.

Conclusions:

  • The developed post-reconstruction RR method offers a practical solution for enhancing PET image quality.
  • This technique provides superior results to the RL algorithm without complex system access.
  • The method holds promise for more accurate quantitative analysis in PET imaging.