Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

223
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
223
Aliasing01:18

Aliasing

136
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
136
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

163
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
163
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

693
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
693
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

437
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
437

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Signatures of correlation of spacetime fluctuations in laser interferometers.

Nature communications·2025
Same author

Sensing with quantum light: a perspective.

Nanophotonics (Berlin, Germany)·2025
Same author

Advantage of Coherent States in Ring Resonators over Any Quantum Probe Single-Pass Absorption Estimation Strategy.

Physical review letters·2022
Same author

Plasmon-Phonon Coupling in Electrostatically Gated β-Ga<sub>2</sub>O<sub>3</sub> Films with Mobility Exceeding 200 cm<sup>2</sup> V<sup>-1</sup> s<sup>-1</sup>.

ACS nano·2022
Same author

Model-Independent Simulation Complexity of Complex Quantum Dynamics.

Physical review letters·2021
Same author

Approaching Quantum-Limited Metrology with Imperfect Detectors by Using Weak-Value Amplification.

Physical review letters·2020

Related Experiment Video

Updated: Jul 4, 2025

Scalable Quantum Integrated Circuits on Superconducting Two-Dimensional Electron Gas Platform
05:39

Scalable Quantum Integrated Circuits on Superconducting Two-Dimensional Electron Gas Platform

Published on: August 2, 2019

9.6K

Accreditation of analogue quantum simulators.

Andrew Jackson1, Theodoros Kapourniotis1, Animesh Datta1

  • 1Department of Physics, University of Warwick, Coventry CV4 7AL, United Kingdom.

Proceedings of the National Academy of Sciences of the United States of America
|January 31, 2024
PubMed
Summary

This article introduces a new method to verify the accuracy of continuous-time quantum simulators. By calculating an upper limit on potential errors, researchers can now confirm if their simulation results are reliable without needing to know the exact internal details of the quantum device. This approach works regardless of the size or complexity of the task, making it a practical tool for current and future quantum hardware.

Keywords:
accreditationanalogue quantum simulationsimulationverificationError EstimationQuantum ComputingHamiltonian DynamicsHybrid Systems

Frequently Asked Questions

More Related Videos

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
12:19

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

Published on: April 4, 2017

8.4K
Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
05:30

Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit

Published on: September 8, 2023

561

Related Experiment Videos

Last Updated: Jul 4, 2025

Scalable Quantum Integrated Circuits on Superconducting Two-Dimensional Electron Gas Platform
05:39

Scalable Quantum Integrated Circuits on Superconducting Two-Dimensional Electron Gas Platform

Published on: August 2, 2019

9.6K
Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
12:19

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

Published on: April 4, 2017

8.4K
Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
05:30

Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit

Published on: September 8, 2023

561

Area of Science:

  • Quantum information science focusing on Accreditation of analogue quantum simulators
  • Computational physics and theoretical quantum computing

Background:

No prior work had resolved the challenge of verifying continuous-time quantum systems without full state tomography. Researchers often struggle to quantify the reliability of complex quantum hardware during large-scale operations. It was already known that digital systems possess established validation techniques. However, analogue platforms lack similar robust frameworks for error estimation. This gap motivated the development of new mathematical bounds for continuous processes. Prior research has shown that universal Hamiltonians provide a path toward programmable quantum control. That uncertainty drove the need for scalable accreditation strategies. The current landscape requires methods that remain efficient as system dimensions increase.

Purpose Of The Study:

The aim of this study is to introduce a formal accreditation protocol for continuous-time quantum simulators. This research addresses the lack of standardized methods for verifying analogue quantum outputs. The authors seek to provide a reliable way to bound errors in complex simulation tasks. This motivation stems from the need to ensure the accuracy of quantum devices as they scale. The researchers intend to create a tool that is independent of the specific nature of the simulation. They address the problem of error accumulation in continuous-time processes. The study aims to facilitate the transition toward more complex and programmable quantum hardware. This work provides a necessary framework for validating results in the absence of perfect error-free conditions.

Main Methods:

Review Approach involves analyzing the mathematical properties of continuous-time quantum evolution. The authors examine the relationship between universal Hamiltonians and error propagation in large systems. They construct an analytical bound that quantifies the divergence between ideal and noisy outputs. This design avoids the computational costs associated with full state tomography. The researchers integrate concepts from hybrid computing to define the protocol steps. They evaluate the scalability of their approach by assessing the independence of overheads from system size. This methodology relies on established theoretical advances to ensure rigorous error estimation. The team validates the framework by demonstrating its applicability to diverse simulation tasks.

Main Results:

Key Findings From the Literature indicate that the protocol successfully provides an upper bound on the variation distance for continuous-time systems. The researchers demonstrate that this bound remains valid regardless of the specific simulation task. Their analysis reveals that the required overheads are entirely independent of the size of the quantum simulator. This finding ensures that the method remains practical for increasingly complex hardware architectures. The authors show that the protocol is compatible with current experimental progress in programmable hybrid devices. Their results suggest that error estimation can be performed without needing to know the internal state of the simulator. The study confirms that the accreditation process is ready for immediate implementation in laboratory settings. These findings establish a robust foundation for verifying analogue quantum computations.

Conclusions:

The authors propose a verification framework that establishes a maximum error threshold for continuous quantum processes. This synthesis suggests that reliable simulation is achievable even in the presence of hardware noise. The researchers imply that their protocol remains effective regardless of the specific simulation task performed. Their work demonstrates that overhead costs do not scale with the complexity of the quantum system. This implies that the method is suitable for long-term integration into experimental workflows. The authors conclude that their approach bridges the gap between theoretical universality and practical implementation. This synthesis highlights the utility of hybrid architectures for validating analogue outputs. The findings suggest that immediate adoption of this protocol can enhance confidence in current quantum simulation results.

The protocol provides an upper bound on the variation distance between probability distributions. This metric quantifies the divergence between an erroneous output and an ideal, error-free simulation result, allowing researchers to bound the total error without requiring full state reconstruction.

The method utilizes strongly universal Hamiltonians to enable programmable control. By leveraging these mathematical structures, the researchers create a flexible framework that supports hybrid analogue-digital operations, which are necessary for implementing the verification steps on existing hardware.

A hybrid analogue-digital architecture is necessary because the digital component facilitates the required control sequences. This integration allows the system to perform the accreditation steps while maintaining the continuous-time nature of the primary simulation task.

The protocol uses the variation distance as a data type to measure output discrepancies. This statistical measure serves as a robust indicator of simulator performance, ensuring that the error bounds remain meaningful across different simulation scales.

The researchers measure the fidelity of the simulation by comparing the output distributions. This phenomenon allows for the detection of errors without needing to characterize every individual component of the quantum device during the simulation.

The authors propose that this protocol is ready for immediate usage in experimental settings. They claim that because the overheads are independent of system size, the method provides a scalable solution for future large-scale quantum devices.