Accurate time-domain and frequency-domain co-simulation approach for OEICs design with Verilog-A

Optics Express
|February 1, 2024
PubMed

Related Concept Videos

Frequency Response of Op Amp Circuits01:20

Frequency Response of Op Amp Circuits

Operational amplifiers (op-amp) are used in signal conditioning, filtering, or for performing mathematical operations such as addition, subtraction, integration, and differentiation. The frequency response of an op-amp is an important aspect that describes how the gain of the amplifier varies with frequency.
Frequency Response and Gain:
The gain of the op-amp, A(ω), is not a constant but a function of the input signal frequency. An op-amp can maintain a constant gain at low frequencies,...
334
Frequency Response of a Circuit01:20

Frequency Response of a Circuit

Inductive circuits present intriguing challenges in electrical engineering, particularly during the transition from the time domain to the frequency domain. This transformation involves converting inductors into impedances and utilizing phasor representation.
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
288
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
97
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
84
Linear time-invariant Systems01:23

Linear time-invariant Systems

A system is linear if it displays the characteristics of homogeneity and additivity, together termed the superposition property. This principle is fundamental in all linear systems. Linear time-invariant (LTI) systems include systems with linear elements and constant parameters.
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
261
Linear Approximation in Time Domain01:21

Linear Approximation in Time Domain

Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
81