Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Highly sensitive OPD-demodulated fiber temperature sensor based on an ultra-long liquid-core with a syringe shape
Abstract:
An optical path difference (OPD)-demodulated fiber temperature sensor based on a Fabry-Perot interferometer with a liquid-core is proposed. The length of the liquid-core reaches more than 3 mm, and it shapes like a syringe. It is fabricated by filling cedar oil into a section of the hollow core fiber with two different inner diameters. The cedar oil whose refractive index is larger than that of silica can work as the liquid-core, and its length changes with the temperature variation sensitively owing to the high thermal expansion coefficient (TEC). Theoretical analysis proves that the temperature sensitivity based on the OPD demodulation is proportional to the length of the liquid-core, and the syringe shape can further amplify the sensitivity greatly. The filling length of the cedar oil can be improved greatly by the inside-instilling method through an ultra-fine silica needle. As a result, the OPD sensitivity is as high as 50.93 µm/°C, which is three orders of magnitude higher than that of most reported sensors. Besides, the sensor also offers excellent repeatability and stability owing to the absence of residual stress in the liquid material.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermosensation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...