Related Experiment Video
Updated: Jul 4, 2025

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
Control of mean arterial pressure using a closed-loop system for norepinephrine infusion in severe brain injury
Alexandre Joosten1, Joseph Rinehart2, Maxime Cannesson3
1Department of Anesthesiology & Perioperative Medicine, David Geffen School of Medicine, Ronald Reagan Medical Center, University of California Los Angeles, 757 Westwood Plaza, Los Angeles, CA, 90095, USA. joosten-alexandre@hotmail.com.
Brain injury patients require precise blood pressure (BP) management to maintain cerebral perfusion pressure (CPP) and avoid intracranial hypertension. Nurses have many tasks and norepinephrine titration has been shown to be suboptimal. This can lead to limited BP control in patients that are in critical need of cerebral perfusion optimization. We have designed a closed-loop vasopressor (CLV) system capable of maintaining mean arterial pressure (MAP) in a narrow range and we aimed to assess its performance when treating severe brain injury patients. Within the first 48 h of intensive care unit (ICU) admission, 18 patients with a severe brain injury underwent either CLV or manual norepinephrine titration. In both groups, the objective was to maintain MAP in target (within ± 5 mmHg of a predefined target MAP) to achieve optimal CPP. Fluid administration was standardized in the two groups. The primary objective was the percentage of time patients were in target. Secondary outcomes included time spent over and under target. Over the four-hour study period, the mean percentage of time with MAP in target was greater in the CLV group than in the control group (95.8 ± 2.2% vs. 42.5 ± 27.0%, p < 0.001). Severe undershooting, defined as MAP < 10 mmHg of target value was lower in the CLV group (0.2 ± 0.3% vs. 7.4 ± 14.2%, p < 0.001) as was severe overshooting defined as MAP > 10 mmHg of target (0.0 ± 0.0% vs. 22.0 ± 29.0%, p < 0.001). The CLV system can maintain MAP in target better than nurses caring for severe brain injury patients.
Brain injury patients require precise blood pressure (BP) management to maintain cerebral perfusion pressure (CPP) and avoid intracranial hypertension. Nurses have many tasks and norepinephrine titration has been shown to be suboptimal. This can lead to limited BP control in patients that are in critical need of cerebral perfusion optimization. We have designed a closed-loop vasopressor (CLV) system capable of maintaining mean arterial pressure (MAP) in a narrow range and we aimed to assess its performance when treating severe brain injury patients. Within the first 48 h of intensive care unit (ICU) admission, 18 patients with a severe brain injury underwent either CLV or manual norepinephrine titration. In both groups, the objective was to maintain MAP in target (within ± 5 mmHg of a predefined target MAP) to achieve optimal CPP. Fluid administration was standardized in the two groups. The primary objective was the percentage of time patients were in target. Secondary outcomes included time spent over and under target. Over the four-hour study period, the mean percentage of time with MAP in target was greater in the CLV group than in the control group (95.8 ± 2.2% vs. 42.5 ± 27.0%, p < 0.001). Severe undershooting, defined as MAP < 10 mmHg of target value was lower in the CLV group (0.2 ± 0.3% vs. 7.4 ± 14.2%, p < 0.001) as was severe overshooting defined as MAP > 10 mmHg of target (0.0 ± 0.0% vs. 22.0 ± 29.0%, p < 0.001). The CLV system can maintain MAP in target better than nurses caring for severe brain injury patients.
More Related Videos
04:02Author Spotlight: Developing Precise and Clinically Relevant Models for Studying Secondary Degeneration in Traumatic Optic Neuropathy
Published on: November 29, 2024
12:15Optimized System for Cerebral Perfusion Monitoring in the Rat Stroke Model of Intraluminal Middle Cerebral Artery Occlusion
Published on: February 17, 2013