Related Experiment Video
Updated: May 13, 2026

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
The value of bronchodilator response in FEV1 and FeNO for differentiating between chronic respiratory diseases: an
Zhaoqian Gong1, Junwen Huang1, Guiling Xu1
1Chronic Airways Diseases Laboratory, Department of Respiratory and Critical Care Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China.
Background:
There is no uniform standard for a strongly positive bronchodilation test (BDT) result. In addition, the role of bronchodilator response in differentiating between asthma, chronic obstructive pulmonary disease (COPD), and asthma-COPD overlap (ACO) in patients with a positive BDT result is unclear. We explored a simplified standard of a strongly positive BDT result and whether bronchodilator response combined with fractional exhaled nitric oxide (FeNO) can differentiate between asthma, COPD, and ACO in patients with a positive BDT result.
Methods:
Three standards of a strongly positive BDT result, which were, respectively, defined as post-bronchodilator forced expiratory volume in 1-s responses (ΔFEV1) increasing by at least 400 mL + 15% (standard I), 400 mL (standard II), or 15% (standard III), were analyzed in asthma, COPD, and ACO patients with a positive BDT result. Receiver operating characteristic curves were used to determine the optimal values of ΔFEV1 and FeNO. Finally, the accuracy of prediction was verified by a validation study.
Results:
The rates of a strongly positive BDT result and the characteristics between standards I and II were consistent; however, those for standard III was different. ΔFEV1 ≥ 345 mL could predict ACO diagnosis in COPD patients with a positive BDT result (area under the curve [AUC]: 0.881; 95% confidence interval [CI] 0.83-0.94), with a sensitivity and specificity of 90.0% and 91.2%, respectively, in the validation study. When ΔFEV1 was < 315 mL combined with FeNO < 28.5 parts per billion, patients with a positive BDT result were more likely to have pure COPD (AUC: 0.774; 95% CI 0.72-0.83).
Conclusion:
The simplified standard II can replace standard I. ΔFEV1 and FeNO are helpful in differentiating between asthma, COPD, and ACO in patients with a positive BDT result.
More Related Videos
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-I: Introduction
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features

