Related Experiment Video
Updated: Jul 4, 2025

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Performance of Febrile Infant Decision Tools on Hypothermic Infants Evaluated for Infection
Kathryn Westphal1,2, Hania Adib3, Vignesh Doraiswamy1,2
1Division of Hospital Medicine, Nationwide Children's Hospital, Columbus, Ohio.
Background:
Given the lack of evidence-based guidelines for hypothermic infants, providers may be inclined to use febrile infant decision-making tools to guide management decisions. Our objective was to assess the diagnostic performance of febrile infant decision tools for identifying hypothermic infants at low risk of bacterial infection.
Methods:
We conducted a secondary analysis of a retrospective cohort study of hypothermic (≤36.0 C) infants ≤90 days of age presenting to the emergency department or inpatient unit among 9 participating sites between September 1, 2016 and May 5, 2021. Well-appearing infants evaluated for bacterial infections via laboratory testing were included. Infants with complex chronic conditions or premature birth were excluded. Performance characteristics for detecting serious bacterial infection (SBI; urinary tract infection, bacteremia, bacterial meningitis) and invasive bacterial infection (IBI; bacteremia, bacterial meningitis) were calculated for each tool.
Results:
Overall, 314 infants met the general inclusion criteria, including 14 cases of SBI (4.5%) and 7 cases of IBI (2.2%). The median age was 5 days, and 68.1% of the infants (214/314) underwent a full sepsis evaluation. The Philadelphia, Boston, IBI Score, and American Academy of Pediatrics Clinical Practice Guideline did not misclassify any SBI or IBI as low risk; however, they had low specificity and positive predictive value. Rochester and Pediatric Emergency Care Applied Research Network tools misclassified infants with bacterial infections.
Conclusions:
Several febrile infant decision tools were highly sensitive, minimizing missed SBIs and IBIs in hypothermic infants. However, the low specificity of these decision tools may lead to unnecessary testing, antimicrobial exposure, and hospitalization.
Related Concept Videos
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Increased Body Temperature
Decreased Body Temperature
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

