Introduction: Parastomal hernia repair remains a challenge. We describe a robotic retromuscular non-keyhole mesh repair using a synthetically reinforced biological mesh (Ovitex) for the repair of complex and/or recurrent parastomal hernia and technical modifications we made along the way to improve our technique. Methods: All patients underwent the described retromuscular parastomal hernia repair. Data was collected in a database and a retrospective analysis was performed on direct postoperative results and early follow-up. Results: Eleven patients underwent the operation. Median follow-up was 12 months. Median LOS was 6 days. Two recurrences occurred. One patient suffered postoperative hematoma and skin necrosis, which healed completely, but did lead to a recurrence. One patient had a significant seroma, which subsided without intervention. Both recurrences were reoperated, and a local repair was performed. Conclusion: This paper is the first to describe a modified robotic Pauli repair for complex and recurrent parastomal hernia, using a synthetically reinforced biological mesh. Results are satisfying so far, especially considering the complexity of the cases.