Diagnostic accuracy of virtual non-contrast CT for aortic valve stenosis severity evaluation
Daniel Lorenzatti1, Pamela Piña2, Jonathan Daich1
1Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine. Bronx, NY, USA.
Background:
Computed tomography aortic valve calcium (AVC) score has accepted value for diagnosing and predicting outcomes in aortic stenosis (AS). Multi-energy CT (MECT) allows virtual non-contrast (VNC) reconstructions from contrast scans. We aim to compare the VNC-AVC score to the true non-contrast (TNC)-AVC score for assessing AS severity.
Methods:
We prospectively included patients undergoing a MECT for transcatheter aortic valve replacement (TAVR) planning. TNC-AVC was acquired before contrast, and VNC-AVC was derived from a retrospectively gated contrast-enhanced scan. The Agatston scoring method was used for quantification, and linear regression analysis to derive adjusted-VNC values.
Results:
Among 109 patients (55% female) included, 43% had concordant severe and 14% concordant moderate AS. TNC scan median dose-length product was 116 mGy∗cm. The median TNC-AVC was 2,107 AU (1,093-3,372), while VNC-AVC was 1,835 AU (1293-2,972) after applying the coefficient (1.46) and constant (743) terms. A strong correlation was demonstrated between methods (r = 0.93; p < 0.001). Using accepted thresholds (>1,300 AU for women and >2,000 AU for men), 65% (n = 71) of patients had severe AS by TNC-AVC and 67% (n = 73) by adjusted-VNC-AVC. After estimating thresholds for adjusted-VNC (>1,564 AU for women and >2,375 AU for men), 56% (n = 61) had severe AS, demonstrating substantial agreement with TNC-AVC (κ = 0.77).
Conclusions:
MECT-derived VNC-AVC showed a strong correlation with TNC-AVC. After adjustment, VNC-AVC demonstrated substantial agreement with TNC-AVC, potentially eliminating the requirement for an additional scan and enabling reductions in both radiation exposure and acquisition time.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...