Related Experiment Video
Updated: Jul 4, 2025

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Evaluation of early period changes in intraocular pressure, ocular biometry and anterior segment after upper eyelid
Hakan Koc1, Serkan Ozen2, Ugur Bayram2
1Department of Ophthalmology, Faculty of Medicine, Giresun University, Giresun, Turkey. hakankoc028@gmail.com.
Purpose:
To investigate the acute effects of upper eyelid blepharoplasty on intraocular pressure (IOP) and ocular biometric parameters.
Method:
This prospective cross sectional study examined the eyes of 49 patients with dermatochalasis. Following a detailed ophthalmological examination, corneal topography was used to evaluate the eyes mesopic and photopic pupil diameter, anterior chamber depth, and corneal astigmatism on the day of surgery and on days first and seventh postoperatively. Ocular biometry was used to assess axial length and intraocular lens power. Goldmann applanation tonometry was used to measure intraocular pressure.
Results:
Forty-nine eyes (26 males and 23 females) of 49 patients aged between 44 and 76 years (mean 61 ± 7.9) were included in our study. The mean anterior chamber depth (ACD) was 2.90 ± 0.37 mm preoperatively, 3.00 ± 0.29 mm at postoperative day first, and 3.04 ± 0.29 mm at postoperative day seventh, and the increase in anterior chamber depth was statistically significant (p < 0.001). The mean astigmatism values were measured as preoperative 0.73 ± 0.69 D, postoperative first day 0.93 ± 0.81 D, and postoperative seventh day 1.26 ± 0.90 D. The increase in astigmatism values was statistically significant (p < 0.001). The mean pupil diameter measurements in the mesopic environment were 4.20 ± 0.61 mm preoperatively, 4.40 ± 0.59 mm on the first postoperative day, and 4.39 ± 0.57 mm on the seventh postoperative day, and there was a statistically significant difference between the three measurements (p = 0.03). The mean IOP measurements of the patients were 15.91 ± 3.51 mmHg preoperatively, 16.81 ± 3.36 mmHg on the first postoperative day, and 16.97 ± 3.13 mmHg on the seventh postoperative day. The increase between these three measurements was statistically significant (p = 0.013).
Conclusion:
This study includes important insights into the potential acute phase impact of blepharoplasty surgery on ocular findings. Patients undergoing upper eyelid surgery should be informed about the possible change in ocular biometric parameters, intraocular pressure, and pupil diameter.