Related Experiment Video
Updated: Jul 4, 2025

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Diagnostic Performance of 99mTc-Sestamibi SPECT/CT and 18F-Choline PET/CT in Locating Hyperfunctioning Parathyroid
Ante Mandic1, Ivana Kraljevic1,2, Tanja Skoric Polovina1
1University Hospital Centre Zagreb, Kispaticeva 12, 10000 Zagreb, Croatia.
Objective:
This study aimed to assess the diagnostic performance of 99mTc-sestamibi SPECT/CT and 18F-choline PET/CT in detecting hyperfunctioning parathyroid glands in patients undergoing surgery for primary hyperparathyroidism (PHPT).
Methods:
A retrospective analysis was conducted on patients who underwent PHPT-related surgery between April 2019 and May 2022. The study focused on patients undergoing either 99mTc-sestamibi SPECT/CT (81 patients) or 18F-choline PET/CT (33 patients) scans before surgery to pinpoint hyperfunctioning parathyroid gland(s). In the majority of patients, 18F-choline PET/CT was performed after negative or inconclusive findings on 99mTc-sestamibi SPECT/CT. Pathohistological reports were utilized as the reference standard for evaluating the accuracy of the imaging findings.
Results:
The study encompassed 83 patients (70 females, 84.3%) with an average age of 57.2 years (24-80 years). The pathohistological analysis identified a total of 98 glands. In a per-lesion analysis, the detection rate of 99mTc-sestamibi SPECT/CT was 57% (95% CI 45.3-68.1), while the detection rate of 18F-choline PET/CT was 90.3% (95% CI 74.3-98.0).
Conclusion:
The results of our study showed the significant usefulness of 18F-choline PET/CT in patients with negative or inconclusive results of 99mTc-sestamibi SPECT/CT in accurately locating hyperfunctioning parathyroid glands in PHPT patients.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...