Related Experiment Video
Updated: Jul 4, 2025

Leveraging Turbidity and Thromboelastography for Complementary Clot Characterization
Published on: June 4, 2020
Features of thromboelastogram in populations exposed to or transferring from high altitude
Zhu Huang1,2, Dong-Xin Huang1,2,3, Yan-Yan Wang1,4
1Pancreatic Injury and Repair Key Laboratory of Sichuan Province, The General Hospital of Western Theater Command, Chengdu, 610000, China.
Background:
Thromboelastogram (TEG) is an effective indicator that monitors the dynamic changes of blood coagulation in real-time. It still remains controversial about the performance and influence of coagulation at high altitude. The present study intends to describe comprehensively the clinical features of TEG in populations exposed to or transferring from high altitude.
Methods:
Two groups were recruited in the present study. Group A included young males who worked at high-altitude (4888 m or 5418 m) areas for some time, while Group B included young males who had recently returned from high-altitude (4888 m or 5418 m) areas. Medical examinations were performed using portable devices. Spearman's test was used to evaluate the correlations between thromboelastogram (TEG) variables and other variables. Logistic regression analysis was used to analyze the factors affecting various abnormal TEG variables.
Results:
A total of 51 adult males were included in the two groups. Significantly increased reaction time (R) and decreased maximum amplitude (MA) were found in group B (P < 0.05). No significant differences were observed in the comparisons of K and angle between the two groups. Various TEG variables were identified to be correlated with different coagulation and biochemical variables. Logistic regression analysis demonstrated that abnormal R was independently associated with direct bilirubin, and abnormal K was independently associated with the platelet count in Group A (P < 0.05). However, none of the factors were independently associated with abnormal TEG variables in Group B.
Conclusion:
Populations exposed to or transferring from high altitudes are characterized by different TEG characteristics. Our findings give a comprehensive description of the complex interaction between TEG indexes, coagulation dynamics, and hematological parameters, which can help guide the development of appropriate medical approaches tailored to the unique needs of these populations.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Measurement of Blood Pressure
Factors Affecting Respiration
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection

