Related Experiment Video
Updated: Jul 4, 2025

Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
Effect of pH on In-Electrospray Hydrogen/Deuterium Exchange of Carbohydrates and Peptides
Jacob B Hatvany1, O Tara Liyanage1, Elyssia S Gallagher1
1Department of Chemistry & Biochemistry, Baylor University, One Bear Place #97348, Waco, Texas 76798, United States.
Abstract:
Carbohydrates are critical for cellular functions as well as an important class of metabolites. Characterizing carbohydrate structures is a difficult analytical challenge due to the presence of isomers. In-electrospray hydrogen/deuterium exchange mass spectrometry (in-ESI HDX-MS) is a method of HDX that samples the solvated structure of carbohydrates during the ESI process and requires little to no instrument modification. Traditionally, solution-phase HDX is utilized with proteins to sample conformational differences, and pH is a critical parameter to monitor and control due to the presence of both acid- and base-catalyzed mechanisms of exchange. For In-ESI HDX, the pH surrounding the analyte changes before and during labeling, which has the potential to affect the rate of labeling for analytes. Herein, we alter the pH of spray solutions containing model carbohydrates and peptides, perform in-ESI HDX-MS, and characterize the deuterium uptake trends. Varying pH results in altered D uptake, though the overall trends differ from the expected bulk-solution trends due to the electrospray process. These findings show the utility of varying pH prior to in-ESI HDX-MS for establishing different extents of HDX as well as distinguishing labile functional groups that are present in different analytes.
More Related Videos
11:32A Hydrogen-Deuterium Exchange Mass Spectrometry HDX-MS Platform for Investigating Peptide Biosynthetic Enzymes
Published on: May 4, 2020
10:24Defining Hsp33's Redox-regulated Chaperone Activity and Mapping Conformational Changes on Hsp33 Using Hydrogen-deuterium Exchange Mass Spectrometry
Published on: June 7, 2018
Related Concept Videos
Extraction: Effects of pH
NMR and Mass Spectroscopy of Carboxylic Acids
While α protons of carboxylic acids absorb at 2–2.5 ppm, β protons absorb further upfield.
Carboxylic acids are easily identified by dissolving them in deuterium oxide, which results in a rapid exchange of the acidic protons with deuterium. This leads to the...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Ion Exchange