Comparing contamination rates of sterile-covered and uncovered transducers for ultrasound-guided peripheral
Yonathan Estrella1,2, Nathan Panzlau3, Kevin Vinokur4
1Department of Emergency Medicine, New York Presbyterian Brooklyn Methodist Hospital, Brooklyn, NY, USA. yonathan1013@gmail.com.
Introduction:
Physicians frequently use point-of-care ultrasound for intravenous access and bloodwork in the ED. Recently, AIUM and ACEP released recommendations on ultrasound-guided peripheral intravenous lines (USPIVs), but there are no agreed upon standardized policies. We sought to determine whether the use of sterile-covered transducers (SCT) decreases the rate of contamination when compared to uncovered transducers (UCT) after standard low-level disinfection (LLD).
Methods:
This is a randomized control trial comparing contamination rates of US transducers between SCT and UCT after their use for USPIV by the vascular access team, also known as the "PICC" team, over a 3-month period. A sample of admitted patient with an USPIV order were included and randomized to SCT (experimental) or UCT (control) arms. Transducers were swabbed and inserted into the SystemSURE Plus Adenosine Triphosphate (ATP) Luminometer to calculate Relative Light Units (RLU). We performed a cost analysis of requiring sterile covers for USPIVs.
Results:
The UCT and SCT arms contained 35 and 38 patients, respectively. The SCT group had a mean of 0.34 compared to the UCT group mean of 2.29. Each sterile cover costs $8.49, and over 3000 USPIVs are placed annually by the "PICC" team.
Conclusion:
Contamination rates were similar among the UCT and SCT groups after LLD. 254 inpatient USPIVs are performed monthly, not including failed attempts or covers used in the ED where USPIV placement is an essential part of ED workflow. This study suggests that the use of SCT does not significantly affect transducer contamination rates. These findings question burdensome regulatory hospital policies that are not evidence-based.
More Related Videos
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...