Related Experiment Video
Updated: Jul 4, 2025

Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Accuracy of a zero-heat-flux thermometer in cardiac surgery, a prospective, multicentre, method comparison study
Carsten Pedersen1, Peter Munch2, Jesper Kjaergaard3
1Department of Cardiothoracic Anesthesiology, Copenhagen University Hospital, 2100, Copenhagen, Denmark. carsten.michel.pedersen@regionh.dk.
Abstract:
Accurate measurement of core temperature is of utmost importance during on-pump cardiac surgery, for detection of hypothermia before cardiopulmonary bypass (CPB), guidance of temperature management on CPB, active rewarming on CPB and guidance of warming therapy after CPB. Most temperature measurement methods are known to become inaccurate during rapid changes in core temperature and suffer from delayed detection of temperature changes. Zero-heat-flux temperature (ZHF) measurement from the lateral forehead may be an alternative, non-invasive method quantifying the core temperature. A prospective, observational, multicentre study was conducted in one hundred patients scheduled for on-pump coronary artery bypass grafting. Core temperatures were measured every minute by two zero-heat-flux thermometer (SpotOn™) and a bladder thermometer and a pulmonary artery catheter (PAC) in the period after induction of anesthesia until CPB. Accuracy and precision of both methods were compared against core temperature measured in the pulmonary artery using the method of Bland and Altman. A high accuracy (around 0.1 °C) and a very good precision (Limits of agreement (LoA) - 0.6; 0.4 °C) were found between zero-heat-flux thermometer and core temperature measured by PAC. Among the two ZHF thermometers the bias was negligible (- 0.003 °C) with narrow LoA of - 0.42 °C and 0.41 °C. In contrast, bias between bladder temperature and PAC temperature was large (0.51 °C) with corresponding LoA of - 0.06 °C and 1.1 °C. ZHF thermometers are in contrast to bladder temperature a reliable core temperature monitor in cardiac surgery during the period after induction of anestesia until CPB. The zero-heat-flux method can provide clinicians reliably with continuous and non-invasive measurements of core temperature in normothermic and mild hypothermic temperature ranges and therefore can be helpful to guide temperature management.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

