Thinner Tibial Spine Fracture Fragments Are Associated With Risk of Fixation Failure
Gregory Benes1, Daniel Badin1, Majd Marrache1
1Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore, Maryland, U.S.A.
Purpose:
To determine the rate of and risk factors for failure of tibial spine fracture (TSF) repair.
Methods:
This was a retrospective review of patients aged 18 years or younger with TSF who underwent arthroscopic repair performed by a single orthopaedic surgeon at a large tertiary academic hospital between 2015 and 2022. Demographic, clinical, injury, fracture, and surgical characteristics were collected. Coronal length and sagittal length and height of the fracture fragment were measured on preoperative plain radiographs and magnetic resonance imaging of the knee.
Results:
Of 25 patients who underwent arthroscopic reduction with internal fixation of TSFs, 2 (8%) experienced fixation failure. In 16 (64%), internal fixation was performed with suture anchors, whereas 8 (32%) underwent internal fixation with screws. There were 19 male patients (76%). There were no differences in demographic factors (age, race, sex, and body mass index), injury characteristics (laterality, mechanism of injury, and activity causing injury), modified Meyers-McKeever fracture classification, or method of internal fixation between the group with fixation failure and the group without failure. Coronal length (14.2 mm vs 18 mm, P = .17) and sagittal length (13.9 mm vs 18.7 mm, P = .17) of the fracture fragment also did not differ significantly between groups. Sagittal height of the fracture fragment was thinner in patients with failure of fixation (4.3 mm) than in those without failure (8 mm) (P = .02).
Conclusions:
Decreased bone thickness of the displaced fragment was associated with an increased likelihood of fixation failure.
Level Of Evidence:
Level III, retrospective cohort study.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Lower Limb: Tibia and Fibula