Frequency and types of pre-analytical errors in a clinical laboratory of a specialized healthcare hospital
Aroofa Tasneem1, Muhammad Zubair2, Zoha Rasool3
1Aroofa Tasneem, MBBS, Resident MCPS. Clinical Pathology, Multan Institute of Kidney Diseases, Multan, Pakistan.
Background & Objective:
The pre-analytical phase, encompassing all preparatory steps leading to the analytical process, represents a critical stage prone to laboratory errors. An assessment of the occurrence and categories of laboratory errors, specifically within the pre-analytical phase of laboratory procedures, can guide in taking timely actions for rectifying errors responsible for damage and loss of samples. This study aimed to assess the frequency and types of pre-analytical errors within a clinical laboratory at the Multan Institute of Kidney Diseases over two years.
Methods:
This research took place at the Multan Institute of Kidney Diseases. Data was extracted from the hospital laboratory records of the period from 1st January 2021 to 31st December 2022. After data compilation, a retrospective cross-sectional methodology was adopted to assess frequency and types of pre-analytical errors within a clinical laboratory. The records underwent a thorough examination to identify pre-analytical errors, which were classified according to their type and occurrence rate.
Results:
Among the 254810 specimens received during the data collection period, a total of 1,722 specimens (0.67% of all collected samples) were found unsuitable for further processing. Amongst the rejected specimens, 718 (41.6%) displayed indications of hemolysis, 388 (22.5%) exhibited clotting, 217 (12.6%) had an insufficient volume and the remaining specimens fell into other miscellaneous categories such as insufficient quantity, unlabeled samples etc.
Conclusion:
The overall percentage of sample rejections in the laboratory was 0.67%. This study provided valuable insights into various reasons, and causes that require improvements to enhance the efficiency and quality of laboratory processes.
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Errors occurring during blood pressure monitoring
Several factors...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Random and Systematic Errors
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...