Comparison of body iodine pool assessment methods before radioiodine therapy
Mustafa Genc1, Aslihan Yildirim2, Nilufer Yildirim3
1Sivas Numune Hospital, Department of Nuclear Medicine, Sivas, Turkey.
Introduction And Objectives:
Radioactive iodine therapy (RAIT) is recommended to reduce the risk of recurrence and metastasis in patients with intermediate-high risk differentiated thyroid cancer (DTC). In preparation for RAIT, stimulation of thyroid-stimulating hormone and reduction of body iodine pool are important for treatment success. For this purpose, patients are asked to reduce their iodine intake before RAIT, and the body iodine pool can be evaluated by measuring iodine excretion in urine before treatment. The aim of our study is to compare the methods used to measure the body iodine pool in the evaluation of the restricted iodine diet (RID) effectiveness applied in the RAIT preparation.
Patients And Methods:
Eighty DTC patients discontinued levothyroxine three weeks before RAIT and followed up with a RID two weeks before treatment. After two weeks of RID, all patients collected their 24-h urine the day before the RAIT date. Patients completed 24-h urine samples on the morning of the RAIT date and also provided a spot urine sample. The estimated 24-h creatinine excretion of the patients was calculated. Estimated 24-h urinary iodine excretion (UIE) was calculated using the spot urine iodine/creatinine (I/C) ratio of the patients. 24-h UIE, iodine concentration in spot urine, I/C ratios in spot urine and estimated 24-h UIE of the patients were analyzed by comparing with each other.
Results:
In 99% of the patients, RID efficiency was sufficient according to 24-h UIE before RAIT. The mean 24-h UIE was 48.81 micrograms/day (mcg/day) in 24-h urine samples taken from the patients to evaluate the body iodine pool. The patients' iodine concentrations in spot urine, I/C ratios in spot urine, and estimated 24-h UIE were all statistically significantly lower than actual 24-h UIE, which was the reference method (p: 0.026 vs <0.001 vs 0.041). Moderate positive correlation between 24-h UIE and iodine concentration in spot urine (r: 0.440), I/C ratio in spot urine (r: 0.493), and estimated 24-h UIE (r: 0.560) found. The strongest correlation was obtained with the estimated 24-h UIE.
Conclusion:
The estimated 24-h UIE obtained by using the I/C ratio in spot urine can be used practically and safely as an alternative to UIE in 24-h urine, which is the gold standard method for evaluating body iodine pool.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:27Autoradiographic Measurements of [14C]-Iodoantipyrine in Rat Brain Following Central Post-Stroke Pain
Published on: July 18, 2016
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...