Related Experiment Video
Updated: Jun 27, 2026

One-step Metabolomics: Carbohydrates, Organic and Amino Acids Quantified in a Single Procedure
Published on: June 25, 2010
Extraction-free analysis in cosmetics by digital image colorimetry, illustrated by the quantification of urea
1Laboratory of Chemistry, Biochemistry and Cosmetology, Department of Biomedical Sciences, University of West Attica, Egaleo, 122 43, Greece.
Abstract:
An extraction-free methodology is proposed for quantifying urea in cosmetics, which relies on urea-mediated decrease of methyl red decoloration by sodium hypochlorite. The method is applied directly to the cosmetic formulation and the resulting color intensity is captured by a smartphone camera. We demonstrate a linear relationship between color intensity and urea concentration in O/W emulsions and a shampoo. This quantification methodology is fully validated by determining its technical characteristics in an O/W cosmetic emulsion: The standard curve is linear over 2.5-30.0 % w/w urea (R2 ≥ 0.985). The coefficient of variation (CV %) on all quality control levels is ≤ 12.54 % for intermediate precision, indicating acceptable precision. Bias is up to ±4.93 % in the emulsion, indicating acceptable accuracy and a countable matrix effect. The proposed analysis setup in combination with a standard addition methodology is applied to verify urea content in purpose-made emulsions: bias is ≤±10.9 %, even in the presence of interfering ammonia. We finally demonstrate that the camera-captured color intensity of an O/W emulsion is proportional to different colorant concentrations in the formulation. This opens the route for further applications of the proposed setup to other ingredients capable of generating a colored product upon suitable reaction inside the formulation matrix.
More Related Videos
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the method...
Urine Studies I: Urinalysis

