Accuracy of 11 intraocular lens calculation formulas in shallow anterior chamber eyes
Haorui Yuan1, Jiaqing Zhang1, Xiaotong Han1
1State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangong, China.
Purpose:
To evaluate the performance of intraocular lens (IOL) calculation formulas and the effect of anterior chamber depth (ACD), axial length (AL) and lens thickness (LT) on the prediction accuracy in shallow ACD eyes.
Methods:
This retrospective, consecutive case-series study included 648 eyes of 648 patients with an ACD < 3.0 mm who underwent phacoemulsification and IOL implantation. Eleven formulas were evaluated: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Hill-Radial Basis Function (RBF) 3.0, Hoffer QST, Kane, Olsen, Pearl-DGS and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T). Subgroup analysis was performed based on ACD, AL and LT.
Results:
Overall, the Hoffer QST and Kane showed no systematic bias. The Kane, EVO 2.0, Hill-RBF 3.0 and Hoffer QST had relatively lower mean absolute error and higher percentages of prediction error within ±0.5 D. For the ACD of 2.5-3.0 mm and AL < 22.0 mm subgroup, the Pearl-DGS exhibited the lowest MAE (0.45 D) and MedAE (0.41 D). Most formulas had a significant myopic bias (-0.43 to -0.18 D, p < 0.05) in the LT < 4.3 mm subgroup and a significant hyperopic bias (0.09-0.29 D, p < 0.05) in the LT ≥ 5.1 mm subgroup.
Conclusion:
The Kane and Hoffer QST were recommended for shallow ACD eyes. In eyes with an ACD between 2.5 and 3.0 mm and a short AL, the Pearl-DGS showed excellent performance. Clinicians need to fine-tune the target refraction according to LT in shallow ACD eyes.
Related Concept Videos
Focusing of Light in the Eye
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...