Proof of concept testing of a positive reference material for in vivo and in vitro sensitization testing of medical
Yusuke Okamoto1, Chie Fukui1, Toshio Kobayashi2
1Division of Medical Devices, National Institute of Health Sciences, Kawasaki, Kanagawa, Japan.
Abstract:
In vivo skin sensitization tests are required to evaluate the biological safety of medical devices in contact with living organisms to provide safe medical care to patients. Negative and positive reference materials have been developed for biological tests of cytotoxicity, implantation, hemolysis, and in vitro skin irritation. However, skin sensitization tests are lacking. In this study, polyurethane sheets containing 1 wt/wt % 2,4-dinitrochlorobenzene (DNCB-PU) were developed and evaluated as a positive reference material for skin sensitization tests. DNCB-PU sheet extracts prepared with sesame oil elicited positive sensitization responses for in vivo sensitization potential in the guinea pig maximization test and the local lymph node assay. Furthermore, DNCB-PU sheet extracts prepared with water and acetonitrile, 10% fetal bovine serum-containing medium, or sesame oil elicited positive sensitization responses as alternatives to animal testing based on the amino acid derivative reactivity assay, human cell line activation test, and epidermal sensitization assay, respectively. These data suggest that the DNCB-PU sheet is an effective extractable positive reference material for in vivo and in vitro skin sensitization testing in medical devices. The formulation of this reference material will lead to the development of safer medical devices that contribute to patient safety.
More Related Videos
12:04Assessment of the Cytotoxic and Immunomodulatory Effects of Substances in Human Precision-cut Lung Slices
Published on: May 9, 2018
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...