Related Experiment Video
Updated: Jul 4, 2025

Endotracheal Intubation of Rabbits Using a Polypropylene Guide Catheter
Published on: November 13, 2017
Articulating Video Stylet Compared to Other Techniques for Endotracheal Intubation in Normal Airways: A Simulation
Simone Messina1,2, Federica Merola1, Cristina Santonocito1
1Department of Anaesthesia and Intensive Care, Policlinico-San Marco University Hospital, Via S. Sofia n 78, 95123 Catania, Italy.
Abstract:
Simulation for airway management allows for acquaintance with new devices and techniques. Endotracheal intubation (ETI), most commonly performed with direct laryngoscopy (DL) or video laryngoscopy (VLS), can be achieved also with combined laryngo-bronchoscopy intubation (CLBI). Finally, an articulating video stylet (ProVu) has been recently introduced. A single-center observational cross-sectional study was performed in a normal simulated airway scenario comparing DL, VLS-Glidescope, VLS-McGrath, CLBI and ProVu regarding the success rate (SR) and corrected time-to-intubation (cTTI, which accounts for the SR). Up to three attempts/device were allowed (maximum of 60 s each). Forty-two consultants with no experience with ProVu participated (15 ± 9 years after training completion). The DL was significantly faster (cTTI) than all other devices (p = 0.033 vs. VLSs, and p < 0.001 for CLBI and Provu), no differences were seen between the two VLSs (p = 0.775), and the VLSs were faster than CLBI and ProVu. Provu had a faster cTTI than CLBI (p = 0.004). The DL and VLSs showed similar SRs, and all the laryngoscopes had a higher SR than CLBI and ProVu at the first attempt. However, by the third attempt, the SR was not different between the DL/VLSs and ProVu (p = 0.241/p = 0.616); ProVu was superior to CLBI (p = 0.038). In consultants with no prior experience, ProVu shows encouraging results compared to DL/VLSs under simulated normal airway circumstances and further studies are warranted.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...

