Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients
Amanda Lynggaard Elkjær1, Esben Uggerby Næser2,3, Katja Thorup Aaen1
1The Department of Rheumatology, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 59, 8200, Aarhus N, Denmark.
Abstract:
Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud's phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland-Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was - 3% (SD: ± 5), 0% (SD: ± 2), and 1% (SD: ± 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...