New multi-injection commutation topology for circuit breakers of HVDC transmission lines
Fady Wadie1, Mahmoud Elsisi2,3, Tamer Eliyan3,4
1Mechatronics and Robotics Engineering Department, Faculty of Engineering, Egyptian Russian University, Badr City, 11829, Egypt. fady-wadie@eru.edu.eg.
Abstract:
Power-sharing between countries has an essential effect on increasing the power system's reliability and allowing a resilient energy market. High voltage direct current (HVDC) transmission systems are preferable for long-distance transmission to decrease power losses. However, HVDC transmission lines have many protection challenges including the differentiability between various types of HVDC circuit breakers (HVDC-CB). Although mechanical HVDC-CBs suffered from long response time, they superseded their solid-state counterparts in terms of price and power losses. In this paper, a multi-injection commutation system MICS-HVDC-CB is developed to provide economic and fast response HVDC-CB. The proposed breaker doesn't add external elements to avoid any price increase but instead modifies the existing topology. The MICS consists of multiple L-C commutation circuits inserted sequentially following the receiving of the tripping signal. The proposed MICS-HVDC-CB was tested upon a real transmission line using ATP simulation software. The results emphasize that the developed MICS-HVDC-CB decreased the arcing time to 38.5% and 20% compared to passive and active DC-CBs. The impact of cooling power, arcing time constant, and fault resistance was also investigated. The results showed the effectiveness of the proposed MICS topology in reducing the arcing time while keeping a simple and economic breaker structure.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
09:26In Situ Time-dependent Dielectric Breakdown in the Transmission Electron Microscope: A Possibility to Understand the Failure Mechanism in Microelectronic Devices
Published on: June 26, 2015
Related Concept Videos
Circuit Breaker and Fuse Selection
In high-voltage systems,...
Power System Three-Phase Short Circuits
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Directional Relays