Microvascular abnormalities induced by hand-transmitted vibration reflects in finger systolic blood pressure: a
Maosheng Yan1,2, Hanjun Zheng1,2, Qian Liu3
1Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment.
Objective:
Local vibration can cause microcirculatory abnormalities such as blood stasis and symmetrical intermittent digital artery vasospasm. Finger SBP (FSBP) measurement is a potential way of assessing vascular components. This study aims to comprehensively investigate the relationship between the occurrence of the vibration-induced white finger (VWF) and changes in FSBP and then set the application value of FSBP measurements in the early diagnosis of VWF.
Methods:
All samples were judgmental sampling from one factory. Totally 50 patients with VWF were the case group, while 50 without occupational hand-transmitted vibration exposure were the control group. FSBP measurements and epidemiological feature investigations were taken.
Results:
There were significant reductions in FSBP level and %FSBP index at both 10 °C and 30 °C in fingers reported VWF ( P < 0.05). The %FSBP abnormal rate of the index, ring and little finger in the VWF group was higher than the control (44.00% vs. 18.00%, 78.00% vs. 26.00%, 64.00% vs. 8.00%). The %FSBP of the ring and little finger had a relatively high application value (area under curve = 0.902, 0.737), while their standard regression coefficients were -0.23 and -0.412. The diagnostic cutoff value of the ring finger was 77.60%, while the sensitivity and specificity were 86.67%.
Conclusion:
FSBP measurements were proven helpful in monitoring and diagnosing VWF prospectively and proved to have great application value in our study. %FSBP of the ring finger was the appropriate diagnostic index in FSBP measurements, while its abnormal value could be set as 80.00%.
Related Concept Videos
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure