Related Experiment Video
Updated: Jul 3, 2025

Magnetic Resonance-Guided Stereotaxy for Infusions to the Pig Brain
Published on: March 31, 2023
The ClearPoint Array Frame: An MRI Compatible System that Supports Non-craniotomy, Multi-trajectory (NCMT)
Youssef J Hamade1, Rajiv Dharnipragada2, Clark C Chen3
1Department of Neurosurgery, University of Minnesota, Minneapolis, Minnesota, USA.
Background:
With continued evolution in stereotactic techniques and an expanding armamentarium of surgical therapeutic options, non-craniotomy stereotactic procedures in neuro-oncology are becoming increasingly complex, often requiring multi-trajectory approaches. Here we demonstrate that the ClearPoint SmartFrame Array (Solana Beach, California, USA), a second-generation magnetic resonance imaging-compatible stereotactic frame, supports such non-craniotomy, multi-trajectory (NCMT) stereotactic procedures.
Methods:
We previously published case reports demonstrating the feasibility of NCMT through the ClearPoint SmartFrame Array. Here we prospectively followed the next 10 consecutive patients who underwent such multi-trajectory procedures to further establish procedural safety and clinical utility.
Results:
Ten patients underwent complex, multi-trajectory stereotactic procedures, including combinations of needle biopsy ± cyst drainage and laser interstitial thermal therapy targeting geographically distinct regions of neoplastic lesions under the same anesthetic event. The median maximal radial error of stereotaxis was 1.0 mm. In all cases, definitive diagnosis was achieved, and >90% of the intended targets were ablated. The average stereotaxis time for the multi-trajectory procedure was 119 ± 22.2 minutes, comparing favorably to our previously published results of single-trajectory procedures (80 ± 9.59 minutes, P = 0.125). There were no procedural complications. Post-procedure, the neurologic condition of 1 patient improved, while the remaining 9 patients remained stable. All patients were discharged home, with a median hospital stay of 1 day (range: 1-12 days). With a median follow-up of 376 days (range: 155-1438 days), there were no 30-day readmissions or wound complications.
Conclusions:
Geographically distinct regions of brain cancer can be safely and accurately accessed through the ClearPoint Array frame in NCMT stereotactic procedures.
More Related Videos
09:00Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex
Published on: April 15, 2015
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022