Related Experiment Video
Updated: Jul 3, 2025

Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
Machine learning identifies esophageal luminal temperature patterns associated with thermal injury in catheter
Yaacoub Chahine1, Tanzina Afroze1, Savannah F Bifulco2
1Division of Cardiology, University of Washington, Seattle, Washington, USA.
Introduction:
Luminal esophageal temperature (LET) monitoring during atrial fibrillation (AF) ablation is widely used to reduce the incidence of endoscopically detected esophageal lesion (EDEL). We sought to assess whether specific patterns of LET variation are associated with EDEL.
Methods:
A high-fidelity multisensor probe was used to record LET in AF patients undergoing radiofrequency ablation (RFA) or cryoballoon ablation (CBA). Explainable machine learning and SHapley Additive exPlanations (SHAP) analysis were used to predict EDEL and assess feature importance.
Results:
A total of 94 patients (38.3% persistent AF, 71.3% male, 72 RFA, and 22 CBA) were included. EDEL was detected in 11 patients (10 RFA and one CBA). In the RFA group, the highest LET recorded was similar between patients with and without EDEL (40.6 [40.1-41]°C vs. 40.2 [39.1-40.9]°C; p = .313), however, the rate of LET rise for the highest recorded peak was higher (0.08 [0.03-0.12]°C/s vs. 0.02 [0.01-0.05]°C/s; p = .033), and the area under the curve (AUC) for the highest peak was smaller (412.5 [206.8-634.1] vs. 588.6 [380.4-861.1]; p = .047) in patients who had EDEL. In case of CBA, the patient with EDEL had a faster LET decline (0.12 vs. 0.07 [0.02-0.14]°C/s), and a smaller AUC for the lowest trough (2491.3 vs. 2629.3 [1712.6-5283.2]). SHAP analysis revealed that a rate of LET change higher than 0.05°C/s and an AUC less than 600 were more predictive of EDEL in RFA.
Conclusion:
The rate of LET change and AUC for the recorded temperature predicted EDEL, whereas absolute peak temperatures did not.
More Related Videos
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...