Related Experiment Video
Updated: May 7, 2026

A Method for Selecting Structure-switching Aptamers Applied to a Colorimetric Gold Nanoparticle Assay
Published on: February 28, 2015
Metal-assisted core-shell plasmonic nanoparticles for small molecule biothiol analysis and enantioselective
Meihuang Zeng1, Linmin Chen1, Xiaocong Hou2
1College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China. xmchen@jmu.edu.cn.
Abstract:
Cysteine (Cys) enantiomorphs, important small-molecule biothiols, participate in various antioxidative, flavoring, and poison-removing processes in the food industry. Current cysteine enantiomorph analysis methods require effective strategies for distinguishing them due to their similar structures and reactivity. Herein, we present a metal ion-assisted enantiomorph-selective surface-enhanced Raman scattering (SERS) biosensor based on an amphiphilic polymer matrix (APM), which can promote cysteine enantiomorph (L/D-Cys) identification. The highly selective molecular orientation is perhaps caused by the intermolecular hydrogen bonding with chiral isomers (metal centers). The experimental results show that the SERS biosensor has a sensitivity-distincting factor toward L-Cys and D-Cys. The linear range is from 1 mmol L-1 to 1 nmol L-1, along with a low limit of detection of 0.77 pmol L-1. Moreover, the fabricated Cu-APM biosensor exhibits remarkable stability and high repeatability, with an RSD of 3.7%. Real food cysteine enantiomorph detection was performed with L-Cys-containing samples of onion, cauliflower, garlic, and apple, and D-Cys-containing samples of vinegar, black garlic, cheese, and beer. The results show that the Cu-APM biosensor can be utilized as a powerful tool for real-time determination of Cys enantiomorphs in different food samples. Thus, the metal-ion-assisted enantiomorph-selective SERS biosensor has potential as an adaptable tool for enantiomorph detection and food sample analysis.

