Related Experiment Video
Updated: Jul 3, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Respiratory exchange ratio overshoot during exercise recovery: a promising prognostic marker in HFrEF
Marco Vecchiato1, Daniel Neunhaeuserer2, Emanuele Zanardo1
1Sports and Exercise Medicine Division, Department of Medicine, University of Padova, University Hospital of Padova, Via Giustiniani 2, 35128, Padova, Italy.
Background And Aims:
Transient increases (overshoot) in respiratory gas analyses have been observed during exercise recovery, but their clinical significance is not clearly understood. An overshoot phenomenon of the respiratory exchange ratio (RER) is commonly observed during recovery from maximal cardiopulmonary exercise testing (CPET), but it has been found reduced in patients with heart failure with reduced ejection fraction (HFrEF). The aim of the study was to analyze the clinical significance of these RER recovery parameters and to understand if these may improve the risk stratification of patients with HFrEF.
Methods:
This cross-sectional study includes HFrEF patients who underwent functional evaluation with maximal CPET for the heart transplant checklist at our Sports and Exercise Medicine Division. RER recovery parameters, including RER overshoot as the percentual increase of RER during recovery (RER mag), have been evaluated after CPET with assessment of hard clinical long-term endpoints (MACEs/deaths and transplant/LVAD-free survival).
Results:
A total of 190 patients with HFrEF and 103 controls were included (54.6 ± 11.9 years; 73% male). RER recovery parameters were significantly lower in patients with HFrEF compared to healthy subjects (RER mag 24.8 ± 14.5% vs 31.4 ± 13.0%), and they showed significant correlations with prognostically relevant CPET parameters. Thirty-three patients with HFrEF did not present a RER overshoot, showing worse cardiorespiratory fitness and efficiency when compared with those patients who showed a detectable overshoot (VO2 peak: 11.0 ± 3.1 vs 15.9 ± 5.1 ml/kg/min; VE/VCO2 slope: 41.5 ± 8.7 vs 32.9 ± 7.9; ΔPETCO2: 2.75 ± 1.83 vs 4.45 ± 2.69 mmHg, respectively). The presence of RER overshoot was associated with a lower risk of cardiovascular events and longer transplant-free survival.
Conclusion:
RER overshoot represents a meaningful cardiorespiratory index to monitor during exercise gas exchange evaluation; it is an easily detectable parameter that could support clinicians to comprehensively interpreting patients' functional impairment and prognosis. CPET recovery analyses should be implemented in the clinical decision-making of advanced HF.
More Related Videos
Related Concept Videos
Acute Respiratory Failure-IV
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...

