Related Experiment Video
Updated: Jul 3, 2025

Preliminary Study on Acupuncture Combined with Grain-sized Moxibustion for Treating Rheumatoid Arthritis with Finger Joint Pain
Published on: May 16, 2025
Thermography at the Elbow Among Patients with Rheumatoid Arthritis: A Comparison with Ultrasound-Detected Joint
York Kiat Tan1,2,3, Rehena Sultana4, Julian Thumboo5,6,7
1Department of Rheumatology and Immunology, Singapore General Hospital, Outram Road, Singapore, 169608, Singapore. tan.york.kiat@singhealth.com.sg.
Introduction:
There is a lack of data on the use of thermography for elbow joint inflammation assessment among patients with rheumatoid arthritis (RA). Hence, we aimed to compare thermography with ultrasonography (a more established imaging modality for joint inflammation assessment) in the assessment of inflammation in the elbows of patients with RA.
Methods:
Standardised minimum (Tmin), maximum (Tmax) and average (Tavg) temperatures at each elbow (medial, lateral, posterior and anterior aspects) were summed to obtain the thermographic parameters MIN, MAX and AVG, respectively. Ultrasound parameters of elbow joint inflammation included total greyscale (TGS) and total power Doppler (TPD) scores. Pearson's correlation coefficient was utilized for correlation analysis between parameters. The relationship between parameters was characterized using simple linear regression.
Results:
Sixty elbows were evaluated from 30 patients with RA in this cross-sectional study. Thermographic parameters (MIN, MAX and AVG) showed significant correlation (P < 0.05) with (1) TPD scores at both elbows (correlation coefficient ranging 0.40 to 0.55) and (2) TGS scores at the right elbow (correlation coefficient ranging 0.39 to 0.42). A statistically significant relationship (P values ranging from 0.002 to 0.033) between parameters was demonstrable as follows: (1) MIN, MAX and AVG versus TPD scores (bilateral elbows) and (2) MIN, MAX and AVG versus TGS scores (right elbow).
Conclusion:
Thermographic temperatures have been demonstrated to correlate with ultrasound-detected joint inflammation at the elbow in patients with RA. The association is more consistently observed with ultrasound PD joint inflammation than its GS counterpart.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

