Related Experiment Video
Updated: Jul 3, 2025

Author Spotlight: Preservation of Bioenergetic Parameters in Peripheral Blood Mononuclear Cells After Cryopreservation
Published on: October 20, 2023
Performance of far forward iceless blood storage containers in controlled cold environments
Antoine Vuong1,2, Clément Derkenne2,3, Stéphane Travers2,4
1Department of Anesthesiology and Intensive Care, Bégin Military Training Hospital, Saint-Mandé, France.
Background:
The Golden Hour Box (GHB), an iceless blood container designed for transfusion closest to the point of injury, is used by military medical teams in remote damage control resuscitation. While its performance is well-established in hot environments, it remains underexplored in cold conditions, a significant consideration in emerging global conflict zones.
Study Design And Methods:
Four GHBs were preconditioned at +4°C or +18°C for 8 h and subsequently exposed to controlled laboratory simulated temperatures of -5, -15, and -25°C for 100 h. The study focused on their capability to maintain an internal temperature between +2 and +6°C, the recommended range for red blood cells unit storage and transport, using calibrated sensors for precise monitoring.
Results:
When exposed to negative Celsius temperatures, GHBs showed varied performance depending on preconditioning temperatures. When preconditioned at +4°C, GHBs maintained an internal temperature within the target range (+2 to +6°C) for 100 h at -5°C, 52 ± 1 h at -15°C, and 29 ± 4 h at -25°C. In contrast, the internal temperature of GHBs preconditioned at +18°C exceeded this range in less than 30 min, then dropped below 2°C more rapidly than those preconditioned at +4°C, occurring within 20 ± 2 h at -15 and 13 ± 1 h at -25°C.
Conclusion:
The GHB, when properly preconditioned, effectively maintains internal temperatures suitable for blood product transport in extreme cold. Future research, including analyses of blood performances, is still needed to validate these results in more realistic operational conditions for use in cold environments.